CABIN HEATER CONT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
HEATER FAN CANNOT BE HEARD RUNNING
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
552
553
554
555
556
557
558
559
560
561
562
TM 55-1520-240-T
13-1.6 CABIN HEATER BLOWER
CIRCUIT BREAKER
WILL NOT STAY CLOSED
13-1.6
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Disconnected
Electrical Power Off
Hydraulic Power Off
Heater Compartment
Acoustic
Blanket Removed
13-10
Change 6
END OF TASK