TM 55-1520-240-T15-6.17 APU STARTS AND RUNS THEN SHUTS DOWN,ESU BITE INDICATES(OVERTEMPERATURE)(HOT START)15-6.17FAULT ISOLATION PROCEDUREINITIAL SETUPTM 55-4920-431-13Applicable Configurations:Equipment Condition:AllTM 55-1520-240-23Tools:Battery DisconnectedAircraft Mechanic’s Tool Kit,Electrical Power OffNSN 5180-00-323-4692Hydraulic Power OffAPU Tester 161226-200General Safety Instructions:Source Low Pressure Compressed AirGogglesMaterials:NonePersonnel Required:Medium Helicopter RepairerReferences:TM 55-1520-240-23Do not use more than 30 psi com-pressed air for cleaning purposes.Debris trajected under pressure cancause injury to eyes. Use source ofcompressed air under 30 psi andeye protection to prevent injury topersonnel.GO TO NEXT PAGEChange 1715-133