TM 55-1520-240-T
15-6.17 APU STARTS AND RUNS THEN SHUTS DOWN,ESU BITE INDICATES (OVERTEMPERATURE)(HOT START)
15-6.17
FAULT ISOLATION PROCEDURE
INITIAL SETUP
TM 55-4920-431-13
Applicable Configurations:
Equipment Condition:
All
TM 55-1520-240-23
Tools:
Battery Disconnected
Aircraft Mechanics Tool Kit,
Electrical Power Off
NSN 5180-00-323-4692
Hydraulic Power Off
APU Tester 161226-200
General Safety Instructions:
Source Low Pressure Compressed Air
Goggles
Materials:
None
Personnel Required:
Medium Helicopter Repairer
References:
TM 55-1520-240-23
Do not use more than 30 psi com-
pressed air for cleaning purposes.
Debris trajected under pressure can
cause injury to eyes. Use source of
compressed air under 30 psi and
eye protection to prevent injury to
personnel.
GO TO NEXT PAGE
Change 17
15-133