APU STARTS AND RUNS
APU STARTS AND RUNS BUT ESU BITE INDICATES
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
737
738
739
740
741
742
743
744
745
746
747
TM 55-1520-240-T
15-6.18 APU STARTS BUT SHUTS DOWN, ESU BITE INDICATES
(OPEN THERMOCOUPLE)
15-6.18
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
References
:
TM 55-1520-240-23
Applicable Configurations
:
TM 55-1500-343-23
All
Tools
:
Equipment Condition
:
Electrical Repairer's Tool Kit,
TM 55-1520-240-23
NSN
5180-00-323-4915
Battery Connected
Multimeter
Electrical Power On
Hydraulic Power Off
Materials
:
None
Personnel Required
:
Aircraft Electrician
END OF TASK