Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
APU STARTS BUT SHUTS DOWN, ESU BITE INDICATES
PANEL LAYOUT
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
738
739
740
741
742
743
744
745
746
747
748
TM 55-1520-240-T
15-6.19 APU STARTS AND RUNS BUT ESU BITE INDICATES
(SHORTED THERMO. PROBE) (WARNING)
15-6.19
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
References
:
TM 55-1520240-23
Applicable Configurations
:
TM 55-1500-343-23
All
Tools
:
Equipment Condition
:
Electrical Repairer's Tool Kit,
TM 55-1520-240-23
NSN 5180-00-3234915
Battery Disconnected
Multimeter
Electrical Power Off
Hydraulic Power Off
Materials
:
None
Personnel Required
:
Aircraft Electrician
END OF TASK
15-136 Change 23
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business