TM 55-1560-307-13&PGENERAL SAFETY INSTRUCTIONSWARNINGELECTRICAL GROUNDING OF THEHELICOPTER. Army regulationsrequire the grounding of the helicopterwhen parked and during all fuelingand defueling operations. No electricalswitches shall be operated exceptthose necessary for servicing duringfueling and defueling. No smoking orflame during all fueling and defuelingoperations.REMOVAL1.Disconnect electrical cannon plug (1) from sensorlevel electro optical (2).2.Remove sensor level electro optical (2) fromadapter (3).INSPECTION1.Visually inspect threads on adapter (3) and newsensor level electro optical (2).2.Check threads on electrical cannon plug and onnew switch.INSTALLATIONInstall new sensor level electro optical.a.Connect electrical cannon plug (1) to sensor levelelectro optical (2).b.Clean up any spilled fuel and check system forproper operation.c.Perform maintenance operational check (MOC).3-18.MAINTENANCE OF FMCP COMPONENTS.REPLACE FUEL PUMP.This task covers:a. Removal.b. Inspection.c. Installation.INITIAL SETUPTools:Bonney WrenchesMaterial/Parts:Fuel Pump (1, Fig C-7), Appx CPackingEquipmentConditions:Refer to Figure 3-8.All ERFS tank cam levers CLOSED.All tee and system coupling valvesCLOSED. Suction hose assembly (14)coupling closed.All electrical power OFF. Refer to Figure 1-1.GENERAL SAFETY INSTRUCTIONSWARNINGELECTRICAL GROUNDING OF THEHELICOPTER. Army regulationsrequire the grounding of the helicopterwhen parked and during all fuelingand defueling operations. Noelectrical switches shall be operatedexcept those necessary for servicingduring fueling and defueling. Nosmoking or flame during all fuelingand defueling operations.3-24