TM 1-1520-240-10
2-3-12
Table 2-3-1. T55-GA-714A DECU BIT Fault Code List/Matrix (Continued)
DECU Fault
Code(s)
Fault
Operational Effect
Pilot Action
Mission Impact
A2
DECU NR set soft fault.
N/A
N/A
Continue Mission
A3
DECU thrust hard fault.
REV light
Unable to start in Primary and
Reversionary
N/A
Abort Mission
A4
DECU NR soft fault.
N/A
N/A
Continue Mission
A5
DECU ECL soft fault.
N/A
N/A
Abort Mission
A6
DECU emergency bus
soft fault.
N/A
Check REV
CONT CB
If CB in, Continue
Mission
If CB out and
cant reset, Abort
Mission
A7
DECU airframe bus soft
fault.
N/A
Check PRI
CONT CB
Back-up power
ON
If CB in, Continue
Mission
If CB out and
cant reset, Abort
Mission
B2
DECU internal N1B hard
fault.
With REV light,
Unable to start in Primary or
Reversionary
N/A
Abort Mission
B2
DECU N1B soft fault.
Without REV light
N/A
Continue Mission
B3
DECU N2B soft fault.
Overspeed system compro-
mised
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission
B4
(DECU Pre-
start BIT
check)
DECU PTIT soft fault.
N/A
Perform REV
mode selected
start. Switch to
PRI when ground
idle is achieved.
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission
B4
(All other
DECU BIT
checks)
DECU PTIT soft fault.
N/A
N/A
Continue Mission
B5
DECU thrust soft fault.
Without REV light
N/A
Continue Mission
B5
DECU thrust hard fault.
With REV light,
Unable to start in Primary or
Reversionary
N/A
Abort Mission