TM 1-1520-240-10
2-3-14
Table 2-3-1. T55-GA-714A DECU BIT Fault Code List/Matrix (Continued)
DECU Fault
Code(s)
Fault
Operational Effect
Pilot Action
Mission Impact
D4
DECU internal power sup-
ply hard fault.
FADEC light
Unable to start in Primary
N/A
Abort Mission
D5
DECU internal power sup-
ply hard fault. DECU inter-
nal hard fault.
FADEC light
Unable to start in Primary
N/A
Abort Mission
D6
DECU internal hard fault.
REV light
Overspeed system compro-
mised
Unable to start in Primary and
Reversionary
N/A
Abort Mission
D6
DECU internal soft fault.
Without REV light
N/A
Continue Mission
D7
DECU internal power sup-
ply hard fault.
FADEC light
Unable to start in Primary
N/A
Abort Mission
D8
DECU internal soft fault
N/A
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission
D9
DECU internal soft fault.
N/A
N/A
Continue Mission
DA
DECU internal power sup-
ply hard/soft fault.
With or without REV light
May be unable to start in Pri-
mary and Reversionary
N/A
Abort Mission
DB
DECU Reversionary sys-
tem hard/soft fault.
With or without REV light
May be unable to start in Pri-
mary and Reversionary
N/A
Abort Mission
DC
DECU internal PTIT soft
fault.
N/A
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission
DD
DECU overspeed system
soft fault.
N/A
N/A
Continue Mission
DE
DECU 400 HZ hard/soft
fault.
With or without REV light
May be unable to start in Pri-
mary and Reversionary
N/A
Abort Mission
DF
DECU internal hard fault.
FADEC light
Unable to start in Primary
N/A
Abort Mission
E1
(DECU Pre-
start BIT
check)
DECU PTIT soft fault.
N/A
Perform REV
mode selected
start. Switch to
PRI when ground
idle is achieved.
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission
E1
(All other
DECU BIT
checks)
DECU PTIT soft fault.
N/A
Make an entry on
the DA Form
2408-13-1 even if
fault code clears.
Continue Mission