TM 1-1520-240-102-3-15Table 2-3-1. T55-GA-714A DECU BIT Fault Code List/Matrix (Continued)DECU FaultCode(s)FaultOperational EffectPilot ActionMission ImpactE2DECU T1 sensor softfault.N/AN/AContinue MissionE3DECU N2A sensor softfault.N/AMake an entry onthe DA Form2408-13-1 even iffault code clears.Continue MissionE4DECU N2B sensor softfault.N/AMake an entry onthe DA Form2408-13-1 even iffault code clears.Continue MissionE5DECU N2 sensor differ-ence soft fault.N/AN/AAbort MissionF1DECU N1A sensor softfault.Unable to restart the engine inPrimaryN/AContinue MissionF2DECU N1B sensor hard/soft fault.With or without REV lightMay be unable to start inN/AAbort MissionF3DECU N1A sensor differ-ence soft fault.N/AN/AAbort MissionF4DECU fuel flow pot softfault.Without FADEC lightUnable to restart the engine inPrimaryFADEC light if engine is shut-downN/AContinue MissionF4DECU fuel flow pot hardfault.With FADEC lightUnable to start in PrimaryN/AAbort MissionF5DECU step count hardfault.FADEC lightUnable to start in PrimaryN/AAbort MissionF6DECU PLA pot soft fault.REV lightUnable to start in Primary andReversionaryN/AAbort MissionF7DECU HMA bleed valvesolenoid hard fault.FADEC lightBleed band inopN/AAbort MissionF8HMA PRI/REV solenoidhard fault.FADEC lightUnable to start in Primary.May not be able to start in Re-versionaryN/AAbort MissionF9HMA Alternator soft fault.N/AN/AContinue MissionFAStart fuel solenoid/ignitionsystem soft fault.May be unable to start in Pri-mary and ReversionaryEnsure that theignition lockswitch in in theON positionContinue MissionFBDECU Reversionary stepcount soft fault.May be unable to start in Pri-mary and ReversionaryN/AAbort MissionFF(on Pre-startBIT check)N/AN/AMove PRI/REVswitch to PRI.Then cycle back-up powerContinue Missionif 88
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business