TM 1-1520-240-MTF
2-34
STARTING ENGINES (CONT.)
BF 6. TROOP ALARM and JUMP LIGHTS Check
operation as required.
a. TROOP ALARM switch ON; the alarm
should sound, then OFF.
b. TROOP JUMP LTS PRESS-TO-TEST.
(1) Select RED.
(2) Select Green.
c. CABIN AND RAMP LIGHTS.
(1) Select NVG Check cabin lights go
from full bright to dim with rheostat.
(2) Select Red/White Check cabin lights
go from full bright to dim with rheostat.
(3) Check Troop Lights go dim when
red/white is selected.
(4) Cabin and Ramp lights OFF Check
cabin and ramp lights off, troop lights
return to bright.
d. TROOP JUMP LTS OFF.
7. Master caution and dome lights Check.
a. Master caution lights Dim. Check master
caution lights and panel lights go dim.
b. DOME SELECT NVG then WHITE.
Check Master Cautions and caution panel
lights go from dim to bright when white
selected. Check both dome lights for NVG
and White.
c. CAUTION lights Press to reset.
d. DOME SELECT OFF.
8. Floodlights (NVG) Check.
a. FLOOD LTS rotary control ON.