TM 1-1520-240-MTF2-37STARTING ENGINES (CONT.)F c. Filter change and Pump fault lights —Check Out.d. Filter Change and Pump Fault lights —Press To Test. Check all individual lightscome on when pressed.e. GND Test switchF (1) Normal — Check all magneticindicators are reset (all black on blackindications).F (2) Test and hold — Check all magneticindicators are tripped (black and whiteindications).(3) XMSN OIL HOT, NO. 1 ENG Chip Det,XMSN Chip Det, and NO. 2 ENG ChipDet caution panel lights and MasterCaution lights — Illuminate in thecockpit.F (4) Reset — Check all bite indicators havereset (all black indications).F f. Main Oil Press, Aux Oil Press, and GroundContact light — Check all on.18. XMSN OIL PRESS gage — Check 0 $ 5 psi allpositions.B*19. Avionics — ON as required.FO 20. EAPS Bypass Door Check.a. NO. 1 and NO. 2 EAPS control boxes.Press-to-test EAPS BYPASS DOORSOPEN light. b. EAPS ENG 1 DOORS switch — OPEN.Check both doors open and BYPASSDOORS OPEN light is on.