TM 1-1520-240-MTF
2-37
STARTING ENGINES (CONT.)
F c. Filter change and Pump fault lights
Check Out.
d. Filter Change and Pump Fault lights
Press To Test. Check all individual lights
come on when pressed.
e. GND Test switch
F (1) Normal
Check
all
magnetic
indicators are reset (all black on black
indications).
F (2) Test and hold Check all magnetic
indicators are tripped (black and white
indications).
(3) XMSN OIL HOT, NO. 1 ENG Chip Det,
XMSN Chip Det, and NO. 2 ENG Chip
Det caution panel lights and Master
Caution lights Illuminate in the
cockpit.
F (4) Reset Check all bite indicators have
reset (all black indications).
F f. Main Oil Press, Aux Oil Press, and Ground
Contact light Check all on.
18. XMSN OIL PRESS gage Check 0 $ 5 psi all
positions.
B* 19. Avionics ON as required.
FO 20. EAPS Bypass Door Check.
a. NO. 1 and NO. 2 EAPS control boxes.
Press-to-test EAPS BYPASS DOORS
OPEN light.
b. EAPS ENG 1 DOORS switch OPEN.
Check both doors open and BYPASS
DOORS OPEN light is on.