TM 55-1520-240-T
9-2.3 AC POWER SYSTEM VISUAL CHECK (Continued)
9-2.3
8. Check apu generator (10).
9. Check No. 1 generator (13).
10. Check No. 2 generator (15).
TASK
RESULT
7. Check three apu current transformers (9).
If any transformer (9) is loose or damaged, tighten
or replace it as required. If wiring to or through
transformers is loose or damaged, tighten or replace
it as required.
If generator (10) is loose or damaged, tighten or re-
place it as required. If wiring to generator is loose or
damaged, tighten or replace it as required. If inlet
screen (11) or exhaust screen (12) are clogged,
clean screen or replace generator.
If generator (13) is loose or damaged, or leaking oil,
tighten or replace it as required. If electrical connec-
tor (14) is loose or damaged, tighten or replace it as
required. If wiring to generator or connector is dam-
aged, repair or replace it as required.
If generator (15) is loose or damaged, or leaking oil,
tighten or replace it as required. If electrical connec-
tor (14) is loose or damaged, tighten or replace it as
required. If wiring to generator or connector is dam-
aged, repair or replace it as required.
FOLLOW-ON MAINTENANCE:
TM 55-1520-240-23:
Left and right transmission baffles closed.
Left and right electrical compartment access doors closed.
Cargo ramp closed.
Change 6
9-63