TM 55-1520-240-T9-2.3 AC POWER SYSTEM VISUAL CHECK (Continued)9-2.38. Check apu generator (10).9. Check No. 1 generator (13).10. Check No. 2 generator (15).TASKRESULT7. Check three apu current transformers (9).If any transformer (9) is loose or damaged, tightenor replace it as required. If wiring to or throughtransformers is loose or damaged, tighten or replaceit as required.If generator (10) is loose or damaged, tighten or re-place it as required. If wiring to generator is loose ordamaged, tighten or replace it as required. If inletscreen (11) or exhaust screen (12) are clogged,clean screen or replace generator.If generator (13) is loose or damaged, or leaking oil,tighten or replace it as required. If electrical connec-tor (14) is loose or damaged, tighten or replace it asrequired. If wiring to generator or connector is dam-aged, repair or replace it as required.If generator (15) is loose or damaged, or leaking oil,tighten or replace it as required. If electrical connec-tor (14) is loose or damaged, tighten or replace it asrequired. If wiring to generator or connector is dam-aged, repair or replace it as required.FOLLOW-ON MAINTENANCE:TM 55-1520-240-23:Left and right transmission baffles closed.Left and right electrical compartment access doors closed.Cargo ramp closed.Change 69-63