TM 55-1520-240-T9-2.4AC POWER SYSTEM OPERATIONAL CHECK (Continued)9-2.4TASKRESULT3.Set BATT switch (9) to ON.MASTER CAUTION lights (10) shall come on. If lights donot come on, go to task 9-1.4.4.Have pilot start apu.APU ON capsule (11) shall come on.5.Set APU GEN switch (12) to ON.NO. 1 RECT OFF and NO. 2 RECT OFF (Without 74)RECT 1 and RECT 2 (With 74) capsules (13 and 14)shall go out. If both capsules are on, go to task 9-2.5. Ifeither capsule is on, go to task 9-1.8 or 9-1.9.6.Checkthat GEN NO. 1 and NO. 2 switches (15 and 16)Ifeither switch (15 or 16) is not at OFF, then set it to OFF.are at OFF.7.Check that NO. 1 GEN OFF and NO. 2 GEN OFFIf either capsule (17 or 18) is out, go to task 9-2.6.(Without 74) GEN 1 and GEN 2 (With 74) capsules(17 and 18)are ON.8.Have pilot start engines and establish 100% rotor rpm.9.Set GEN NO. 1 switch (15) to TEST.NO. 1 GEN OFF (Without 74) GEN 1 (With 74) capsule(17) shall go out. If it does not, check ground stud GD100(STA 594, WL 76, LBL 10), for security and good bond tostructure. If capsule (17) still does not go out, go task9-2.7.10.Set GEN NO. 1 switch (15) to ON.NO. 1 GEN OFF (Without 74) GEN 1 (With 74)capsule(17) shall stay out. NO. 1 RECT OFF NO. 2 RECT OFF(Without 74)RECT 1 and RECT 2 (With 74) capsules(13 and 14) shall stay out. If capsule (17) comes on andstays on, go to task 9-2.8.11. Have pilot shutdown apu. APU ON capsule (11) shall go out. NO. 1 RECT OFF andNO. 2 RECT OFF (Without 74)RECT 1 and RECT 2(With 74) capsules (13 and 14) shall stay out. If theycome on, go to task 9-2.9.GO TO NEXT PAGEChange 19 9-65