TM 55-1520-240-T9-2.4 AC POWER SYSTEM OPERATIONAL CHECK9-2.4INITIAL SETUPReferences:Applicable Configurations:AllTM 55-1520-240-23TM 55-1520-240-10Tools:Equipment Condition:NoneTM 55-1520-240-23:Battery ConnectedMaterials:NonePersonnel Required:Aircraft ElectricianArmv Rotary Wing Aviator (2)TASKRESULTCHECK CIRCUIT BREAKERSCheck that following circuit breakersNO. 1 PDP are closed.onIf any circuit breaker (1 through 5) is open, close it.onIf any circuit breaker (6, 7, or 8) is open, close it.CONT AC (1)CAUTION PNL (2)NO. 1 XFMR RECT (3)AC BUS TIE (4)NO. 1 REV CUR CO (5)Check that followingNO. 2 PDP are closed.2.circuit breakersAC BUS TIE (6)NO. 2 XFMR RECT (7)NO, 2 REV CUR CO (8)9-64Change 4