TM 55-1520-240-T
8-1.7 NO HEAT FELT ON LEFT OR RIGHT PITOT TUBE,
PITOT SWITCH AT ON
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit.
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
68F10 Aircraft Electrician
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23
Battery Connected
Electrical Power On
Hydraullc Power Off
8 - 1 .7
GO TO NEXT PAGE
8 - 1 2