TM 55-1560-307-13&P12. Repeat steps 7 thru 12 for each tank.13. Disconnect D-1 pressure refueling hose (6) frommanifold hose (3), and wipe up any fuel that may havedripped.14. Disconnect grounding wire (1) from tank receptacle(2).15. Secure fuel truck and aircraft.3-14.SUCTION DEFUELING.This task covers:a.Grounding procedures.b.Defueling ERFS tanks.INITIAL SETUPTools:Flashlight (explosion proof).Materials/Parts:Fuel JP-4,-5,-8 (items 7, 8, 9, Appx D)Refueling TruckRefueling Adapter Nozzle, P/N AE82605REquipmentConditions:Same as gravityrefueling.Refer to Figure 3-2.DEFUELING1.Ground helicopter as required.2.Connect fuel hose ground wire (1) to tank groundreceptacle (2).3.Remove dust cap from coupling assembly on hose(3).4.Remove fuel filler port (4) cap.5.Install adapter (5) to manifold hose (3), and connectfuel truck hose (6) to adapter.6.Open all tank and hose cam levers for tanks to bedefueled.7.With an explosion proof flashlight, monitor fuel leveluntil tank is empty.8.Secure tank and proceed to next tank as required.9. After defueling all tanks, disconnect defueling hose(6) and ground wire (1).10. Reinstall dust cap on manifold hose (3).11. Secure fuel truck and helicopter.3-15.MAINTENANCE OF ERFS COMPONENTS.REPLACE ANY SYSTEM FUEL HOSE.This task covers:a. Removal.b. Inspection.c. Installation.INITIAL SETUPTools:NoneMaterials/Parts:Fuel Hose (6,7,8,15, Fig C-2), Appx CEquipmentConditions:Refer to Figures 3-3 and 3-4.ALL ERFS tank cam levers CLOSED.All tee and system coupling valvesCLOSED.3-16
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business