CONTROLS/
INDICATOR
FUNCTION
line-select switch to return to
edit CONTROLS/screen.
When complete, press RTN
line-select switch to load
message into memory and to
return to top-level screen.
Shutdown Procedures Set
function switch to OFF. Gent-
ly pull and turn function
switch to zeroize.
(ZERO) position to erase pre-
programmed information, in-
cluding all fills. Zeroize func-
tion is operational regardless
if system is on or off.
Emergency Commu-
nication
The mode used during emer-
gencies is determined by the
datafill. The equipment oper-
ates normally for mode selec-
ted. Set mode switch to EM-
ER. Press the PTT switch to
transmit. If in ALE mode, an
ALE call is placed to the se-
lected address.
Figure 3-2-8. Control/Display Panel, HF Radio Set
(AN/ARC-220)
3-2-25. Voice Security Equipment TSEC/KY-100.
Voice security equipment (TSEC/KY-100), when
installed, provides two-way clear or secure half-duplex
voice/data communication for the HF radio system (AN/
ARC-200). Power to operate the TSEC/KY-100 is sup-
plied by the No. 2 DC bus through the HF KY-100 circuit
breaker located on the No. 2 PDP.
3-2-26. Controls, Indicators, Connectors and Func-
tion (TSEC/KY-100, Z-AVH) (fig. 3-2-9)
CONTROLS/
INDICATOR
FUNCTION
MODE Switch
Six position rotary switch
used to select one of the op-
erational modes.
PT
Plaintext mode. Allows re-
ception or transmission of un-
encrypted analog voice.
EB
Emergency Back-up mode.
Uses the emergency back-up
key to encrypt voice for trans-
mission or reception.
CT
Ciphertext mode. Allows
transmission of encrypted
voice or data and reception
of encrypted or unencrypted
voice or data, and non-coop-
erative terminal rekeying.
RK
Remote Keying mode. Per-
mits KY-100 to perform auto-
matic and manual rekey op-
erations.
OFFLINE
Disables communications
and gives access to the sys-
tem of menus used to select
mode settings, self-test fea-
tures, and filling the KY-100
with crypto-variables.
Z ALL
(PULL)
Zeroize mode. Erase all cryp-
tographic data stored in the
KY-100 except the Emergen-
cy Back-up Key.
CIK Receptacle
Interfaces with a Crypto-
graphic Ignition Key which is
needed to enable all secure
voice and data communica-
tions. This function is cur-
rently disabled.
DSPL/OFF BRT
Control
Two-function rotary switch
which controls the on/off sta-
tus and backlight intensity of
the LCD display.
PNL/OFF BRT
Control
Two-function rotary switch
which controls the on/off sta-
tus and backlight intensity for
the overall front panel.