TM 1-1520-240-103-2-27p. Push the (up arrow) or (right arrow) buttonuntil the desired receive level is displayed.q. Push the INIT button. The N in RXPTV N will stopflashing.r. Push the (up arrow) or (right arrow) button untilthe Operating Mode is displayed. This completes theReceive Plaintext Volume adjustment.3-2-33. Standard Operation.These procedures describe normal transmit/receive op-eration for cipher text and plaintext voice messages.a. Rotate the KY-100 PRESET switch to MAN (formanual selection) or the desired preset position.b. For ciphertext operation: Place the MODE switchin CT. Ciphertext messages can now be transmitted orreceived. If the CT, CT ONLY menu is set for CT, plaintextmessages can also be received. When transmitting inciphertext, the TX an V enunciators will be lit. Whenreceiving a ciphertext message, the RX and V enuncia-tors will be lit. When receiving a plaintext message, thePT enunciator will be lit.c. For plaintext operation: Place the MODE switch inPT. The CT, CT ONLY menu must be set for CT to be ableto transmit or receive plaintext messages. When trans-mitting in plaintext, the TX enunciator will be lit. Whenreceiving a plaintext message, the RX and PT enuncia-tors will be lit.3-2-34. Troubleshooting.Follow these procedures if the KY-100 displays a FAILmessage during equipment configuration or operation.a. Rotate the KY-100 PRESET switch to the PWROFF position.b. Place the MODE switch in the OFFLINE position.c. Rotate the RESET switch to MAN.d. If the KY-100 does not display a FAIL messageafter self test: Return to normal operation.e. If the KY-100 does display a FAIL message afterself test: Rotate the PRESET to the PWR OFF position.f. Pull the MODE switch and rotate it to the Z ALLposition.g. Follow the COLD START Procedures.h. If the KY-100 does not display a FAIL messageafter self test: Return to normal operation.i. If the KY-100 does display a FAIL message afterself test: Notify maintenance.3-2-35.Off-Line Tests.The off-line TEST menu consist of automatic (AUTO)tests, user-selectable (USER) tests and software version(VERSION) checking procedures.a. Preliminary.(1)Set the KY-100 MODE control to the OF-FLINE position.(2)The display will indicate TEST which is thefirst OFFLINE menu. (3)Press the INIT pushbutton to access theTEST submenus.(4)Press the (up arrow) or (right arrow)pushbutton until the desired sub-menu option (AUTO orUSER) is displayed.(5)Proceed to paragraph b, c or d as applica-ble. b. Automatic (AUTO) Tests.(1)With AUTO displayed, press the INIT push-button to start the automatic tests.(2)At the conclusion of the automatic tests, thetest results will be presented in the display.(3)If the automatic test are successful, PASSwill be displayed and a pass tome will be heard. Next, thedisplay will indicate USER which is the next sub-menu.To perform the USER tests, proceed to paragraph c. Toexit, rotate the MODE control switch out of the OFFLINEposition.(4)If a failure is detected during the automatictests, a FAIL message will be displayed.c. User Tests.(1)With USER displayed, press the INIT push-button to start the user tests.(2)PT LOOP will be momentarily displayed toindicate that a plaintext loopback test will be performed.Next, a PTT prompt is displayed.(3)Depress and hold the PTT switch and, witha TALK prompt displayed, speak into the microphone.Looped back plaintext voice will be heard in the handsetreceiver.(4)Release the PTT switch.(5)CT LOOP will be momentarily displayed in-dicating that the KY-100 is in the cipher text loopbackmode. Next, a PTT operator prompt is displayed.(6)Press and hold PTT switch and, with a TALKprompt displayed, speak into the microphone until theTALK prompt disappears (approximately 15 seconds).(7)Release the PTT switch. The LISTENprompt is displayed. Listen to synthesized speech at thereceiver. Upon completion of the speech loopback, ob-serve that PANEL is displayed.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business