TM 1-1520-240-MTF2-45STARTING ENGINES (CONT.) BF*38. Flight Control Travel Check — FLT CONTRHYDRAULIC switch — BOTH. With slowsmooth flight control inputs, check each axisindividually for smoothness of operation and fulltravel. While mixing pitch, roll, and yaw axiscontrol inputs, check for smoothness ofoperation. Check for minimum cyclic stick travelof 7 inches forward and 4 inches aft.a. FLT CONTR HYDRAULIC switch to NO. 1— ON. Check as follows:(1) NO. 2 HYD FLT CONTR caution light —ON.F (2) FLT CONTR NO. 2 PRESSUREindicator — Zero $ 50psi(3) MASTER CAUTION light — On, thenRESET.(4) With slow smooth flight control inputs,check each axis for smoothness ofoperation and full range of travel.b. Flight Control Hydraulic switch — BOTH.F (1) FLT CONTR HYDRAULIC PRESSURE— Check normal operating range (2) NO. 2 HYD FLT CONTR caution light —Out.c. FLT CONTR HYDRAULIC switch to NO. 2— ON. Check as follows:(1) NO. 1 HYD FLT CONTR caution light —On.F (2) FLT CONTR NO. 1 Pressure Indicator— Zero " 50 psi.(3) MASTER CAUTION light — Check onthe RESET.