TM 1-1520-240-MTF2-48STARTING ENGINES (CONT.) B41. 712 NO. 1 and NO. 2 ENGINE BEEP TRIMswitch — DECREASE for 8 seconds.42. Ignition Lock — ON.BF*43. Area — Clear for start.NOTEIf the start is not normal, abort it. If a second startis attempted, wait at least 15 seconds after N1tachometer indicates zero before starting. This willallow sufficient time for fuel to drain out of thecombustion chamber.CAUTIONSand and debris within the EAPS will beejected when the EAPS fan is operating.Personnel shall stand clear of the exhaustwhen fan is turned on.NOTEThe EAPS fans have high start up electrical powerrequirements. To prevent an overload, the fansmust be turned on one at a time. The first fan mustbe allowed to stabilize for 10-15 seconds beforethe second fan is turned on.BO*44. EAPS FAN NO. 1 and NO. 2 switches — ON,(one at a time). Allow first fan to stabilize for10-15 seconds before the second fan is turnedon.