TM 1-1520-240-MTF
2-49
STARTING ENGINES (CONT.)
CAUTION
With the DASH actuator set to 36 inches and
electrically disconnected, neutral on the stick
position is 3/4 $ 1/4 inch aft of neutral.
45.
714A Abort Start Check.
F a. Fire guard Posted, Rotor blades clear.
b. Left main fuel pump switches on Check
L FUEL PRESS caution lights out.
c. XFEED Open check R FUEL PRESS
caution light out.
d. ENG COND lever GND.
e. ENG START switch to 1 until N1 reaches
10% and release.
f. Prior to completion of start sequence (30 -
40% N1), place ENG 1 ECL to STOP.
F g. Verify start was aborted and check for leaks
h. Repeat steps d - g for ENG 2.
NOTE
Wait at least 15 seconds after N1 reaches zero
before attempting another start. This will allow
time for fuel to drain out of the combustion
chamber.
NOTE
Ensure DECU reads 88 with ECL in ground prior
to restarting either engine.