TM 1-1520-240-MTF2-49STARTING ENGINES (CONT.) CAUTIONWith the DASH actuator set to 36 inches andelectrically disconnected, neutral on the stickposition is 3/4 $ 1/4 inch aft of neutral.45.714A Abort Start — Check.F a. Fire guard — Posted, Rotor blades clear.b. Left main fuel pump switches on — CheckL FUEL PRESS caution lights out.c. XFEED — Open check R FUEL PRESScaution light out.d. ENG COND lever — GND.e. ENG START switch to 1 until N1 reaches10% and release.f. Prior to completion of start sequence (30 -40% N1), place ENG 1 ECL to STOP.F g. Verify start was aborted and check for leaksh. Repeat steps d - g for ENG 2.NOTEWait at least 15 seconds after N1 reaches zerobefore attempting another start. This will allowtime for fuel to drain out of the combustionchamber.NOTEEnsure DECU reads 88 with ECL in ground priorto restarting either engine.