TM 55-1520-240-PMPHASE NO. _____Area Name and No.Aircraft Serial No.DateRAMP AREA #8InspectPhaseNo’sInspection RequirementsStatusFaults and/or RemarksAction TakenInitialALL8.27 Troop alarm arm bell and lights forcondition and security.ALL8.28 Utility hydraulic return modulehousing, mount structure, and transfercylinder for leakage, cracks, buckling,and damage.ALL/C8.29 Flight control links and bellcranksthroughout the aft cabin area forsecurity, damage, and corrosion.Connecting link swaged inserts forevidence of looseness.ALL8.30 Fire bottles for pressure and wireconnectors. System tubing for securityand condition.ALL/C8.31 Bellcrank supports at STA 534.00(left and right) and adjacent structurefor security, corrosion, and cracks.ALL8.32 Fuel and crossfeed valves andhoses for condition and security.ALL8.33 Inspect P3 drain cartridge plastictube (LH and RH) for cracks, security,and broken or missing hardware.(With 74 )"FOD REMINDER"Check work area for tools and parts after completion of maintenance and inspection.2-61