TM 55-1520-240-PM
PHASE NO. _____
Area Name and No.
Aircraft Serial No.
Date
RAMP AREA #8
Inspect
Phase
Nos
Inspection Requirements
Status
Faults and/or Remarks
Action Taken
Initial
ALL
8.27 Troop alarm arm bell and lights for
condition and security.
ALL
8.28 Utility hydraulic return module
housing, mount structure, and transfer
cylinder for leakage, cracks, buckling,
and damage.
ALL/C
8.29 Flight control links and bellcranks
throughout the aft cabin area for
security, damage, and corrosion.
Connecting link swaged inserts for
evidence of looseness.
ALL
8.30 Fire bottles for pressure and wire
connectors. System tubing for security
and condition.
ALL/C
8.31 Bellcrank supports at STA 534.00
(left and right) and adjacent structure
for security, corrosion, and cracks.
ALL
8.32 Fuel and crossfeed valves and
hoses for condition and security.
ALL
8.33 Inspect P3 drain cartridge plastic
tube (LH and RH) for cracks, security,
and broken or missing hardware.
(With 74 )
"FOD REMINDER"
Check work area for tools and parts after completion of maintenance and inspection.
2-61