EXTERNAL CARGO HOOK SYSTEM OPERATIONAL CHECK (Continued) - TM-55-1520-240-T-3_854
FWD OR AFT HOOK LOADED LIGHT IS LIT WHEN CARGO HOOK IS UNLOADED (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
772
773
774
775
776
777
778
779
780
781
782
TM 55-1520-240-T
16-1.5 FWD OR AFT HOOK LOADED LIGHT IS LIT
16-1.5
WHEN CARGO HOOK IS UNLOADED
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
68F20 Aircraft Electrician
Applicable Configurations:
All
References
:
TM 55-1520-240-23
Tools:
Electrical Repairer's Tool Kit
Equipment Condition
:
NSN
5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials
:
Electrical Power On
None
Hydraulic Power Off
GO TO NEXT PAGE