TM 55-6930-212-10
b.
Depress thumbwheel INSERT switchlight. Simulator initializes to start of demo. FREEZE lamps blinks and then
goes steady. DEMO REPLAY ACTIVE message is displayed. At this time, briefing message is played back. At
end of briefing, simulator remains in freeze.
c.
Depress AUDIO RECORD ENABLE switchlight.
d.
Depress COMMENTARY RECORD switchlight.
e.
Prepare to speak commentary.
f.
Depress FREEZE switchlight. FREEZE lamp extinguishes. Demo begins playing back.
g.
Speak commentary while keying microphone as demo proceeds according to prescribed scenario.
h.
At end of demo, AUDIO RECORD ENABLE and COMMENTARY RECORD lamps extinguish.
i.
Depress thumbwheel DELETE switchlight. Commentary audio has been recorded.
8-40. PLOT STORE.
8-41. During training mode, the forward CRT contents can be stored on disk for later recall or for printing as hardcopy.
Twenty plot stores can be made before printing. Each plot store is called a snapshot. A snapshot is produced each time
the IOS STORE PLOT switchlight is depressed.
8-42. PRINT PLOT.
8-43. After all plots are stored, a printout of the stored plots (snapshots) can be requested from the hardcopy unit. When
the printout is complete, the PRINT PLOT indicator extinguishes, and a message is displayed that more plots can be
stored. Average time for one snapshot is 45 seconds from storage to printing.
8-44. ADMINISTRATIVE INTERCOMMUNICATION SYSTEM.
8-45. Private communication between the IOS and the computer room or between the IOS and observer is provided via
an administrative ICS network. When the COMP ROOM switchlight at the IOS is illuminated, an alerting bell rings in the
computer room. (This alerting bell is reset when the call is answered in the computer room.) If the computer room
initiates a call, the COMP ROOM switchlight blinks until the call is answered at the IOS. When the OBS switchlight is
illuminated, private communication with the observer is possible. Simultaneous actuation of the OBS and COMP ROOM
switchlights allows three-way communication over the private ICS network.
8-46. ENVIRONMENTAL/VISUAL CONDITIONS.
8-47. Environmental and visual conditions can be edited by selecting CRT page 020 or 021. Edit appropriate line by
typing the line number, depressing the SPACE key, typing the value, and depressing the ENTER key.
8-31