TM 1-1520-240-MTF
4-34
5. AFCS SYSTEM SEL OFF.
a. NO. 1 & NO. 2 AFCS OFF caution lights on.
6. MASTER CAUTION light RESET.
O. HEATING/VENT BLOWER OPERATION.
Reference:
TM 1-1520-240-10
1-40.
1. HEATER function switch VENT BLOWER
ONLY. AIR CONTROL knobs PULL and
check operation.
2. COCKPIT AIR CONTROL knobs Pilot and
copilot, PULL.
3. Right Main Fuel pump switches ON.
4. HEATER function switch HEATER ON.
5. HEATER START switch Press. Check
ignition (within 10 seconds).
6. CABIN TEMP SELECTOR Check heater
operation and rheostat from COLDER to
WARMER.
a. Heat Distribution check.
(1) For Maximum Cockpit Heat proceed as
follows:
(a)
Pilot and Copilot cockpit air control
knobs Pull.
(b)
DEFOG or DEFROST handle
PULL.
(c)
CABIN AIR handle PUSH.
(d)
CABIN TEMP SEL switch Full
clockwise.
(2) For maximum Cabin heat proceed as
follows:
(a)
Pilot and copilot air control knobs
Push.